Electrical Safety

Electrical safety

The lighting fixtures are designed and manufactured following the EN 60598 / VDE 0711 standards.

Most lightings have the test mark on the type plate. The rest of the luminaires have been or will submit for certification, but the certification and approval procedure is still ongoing. We can provide information on the status of the certification procedure at any time. Special orders are made according to the above set of rules. All lights are subject to continuous monitoring during production and quality control. All luminaires are subject to continuous production and quality control.

Safety symbols

The ENEC symbol (European Norms Electrical Certification) is a European test and certification symbol for luminaires and electrical components in luminaires. The number 10 with or without the VDE symbol signifies that the test/certification symbol was issued by the VDE Institute for Testing and Certification.

Surface-mounted luminaires with this symbol are not suitable for direct installation on normally flammable building materials.

Luminaires bearing this symbol are suitable for business premises where dust or fibrous material present a fire hazard due to their limited surface temperatures (VDE 0711 Part 2 - 24).

Recessed luminaires with this symbol are not suitable for direct installation in normally flammable building materials.

Luminaires and power supply units bearing this symbol must not be in direct contact with thermal insulating materials.

The symbol = ... °C in accordance with DIN EN 60 598 / VDE 0711 indicates the permissible ambient temperature at which a luminaire is allowed to be operated. Our luminaires are generally designed for an ambient temperature ta = 25 °C, i.e. for indoor use.

The CE symbol is affixed at the manufacturer’s responsibility and is not a safety symbol. The manufacturer uses it to document conformity with European Union directives.

The number alongside the CE symbol indicates that an inspection and certification body checks compliance with the guidelines.

Protection classes

These classes provide information on a luminaire’s stability in withstanding the penetration of dust, solid bodies and water in accordance with EN 60598/VDE 0711. The respective degree of protection IP (International Protection) is printed on the luminaire as a number system according to IEC 529. You can find the classification of the degrees of protection in accordance with EN 60598 in the table on this page.

Body protection

IP 1xprotection against penetration of foreign bodies ≥ 50 mm
IP 2xprotection against penetration of foreign bodies ≥ 12 mm
IP 3xprotection against penetration of foreign bodies ≥ 2,5 mm
IP 4xprotection against penetration of foreign bodies ≥ 1 mm
IP 5xprotection against harmful dust deposits
IP 6xprotection against dust entry

Water protection

IP x1protection against drops of water falling vertically
IP x2protection against drops of water from angles up to 15°
IP x3protection against showers up to 60°
IP x4protection against splash water
IP x5protection against water jets
IP x6protection against heavy downpours
IP x7protection against immersion
IP x8…mprotection against submersion

Safety classes

Safety class I designates luminaires with an earth connection. In the event of a fault, the power supply is switched off by an overload/residual current protective devices.

Safety class IIdesignates luminaires that have not only functional insulation but also additional protective insulation. Under fault conditions, no dangerous voltage can reach metal parts which can be touched. Many safety class I luminaires are also available in safety class II. Please contact us.

Safetyclass III designates luminaires operating on extra-low safety voltage. They can be connected only to safety transformers in accordance with EN 61558/VDE 0570, EN 61347/VDE 712 or VDE 0100 Part 410. The transformer must be approved for this type of installation.

DO YOU HAVE A QUESTION?

Time zones mean nothing at La-Luce with our partners having 24hr a day access to quotations, product support and order status updates. LA-Luce products are assembled at our production facility near Milan Italy and we offer a five year extended warranty on selected products. We take pride in our aftersales support, maintaining exceptional relationships with key specifiers and contractors.

    Up
    q

    Lumoo is a global architectural lighting
    company based in Copenhagen

    Opening Hours

    monday

    Closed

    saturday

    10 - 16

    Tuesday - Friday

    10 - 18

    q

    Subscribe to Newsletter